Login / Signup

No optical coherence tomography changes in premanifest Huntington's disease mutation carriers far from disease onset.

Rahel Dominique SchmidJana RemlingerMathias AbeggRobert HoepnerRainer HoffmannCarsten LukasCarsten SaftAnke Salmen
Published in: Brain and behavior (2022)
In this cross-sectional cohort of genetically determined pre-HD participants, neurodegenerative features were not detected with retinal layer segmentation. Since our pre-HD collective was more than 16 years before disease onset, OCT may not be sensitive enough to detect early changes.
Keyphrases
  • optical coherence tomography
  • cross sectional
  • diabetic retinopathy
  • deep learning