Limited accuracy of transurethral and periurethral intrasphincteric injections of cellular suspension.
Anna BurdzińskaBartosz DybowskiWeronika Zarychta-WiśniewskaAgnieszka KuleszaJakub HawrylukAgnieszka Graczyk-JarzynkaPatryk KaupaZdzislaw GajewskiLeszek PaczekPublished in: Neurourology and urodynamics (2018)
Although majority of cell depots were administrated accurately into the urethral wall, the precise delivery of cells into EUS is limited regardless of injection method. The insufficient accuracy of cell delivery into EUS and cell suspension leakage can contribute to the low efficacy of cell therapy in human patients with SUI.