Login / Signup

Prolonged Use of an Automated Insulin Delivery System Improves Sleep in Long-Standing Type 1 Diabetes Complicated by Impaired Awareness of Hypoglycemia.

Susan Kohl MaloneAustin M MatusAnneliese Js FlattAmy J PeleckisLaura GruninGary YuSooyong JangJames WeimerInsup LeeMichael R RickelsNamni Goel
Published in: Journal of diabetes science and technology (2023)
AID improved sleep initiation and maintenance. Improved awareness of hypoglycemia, reduced hypoglycemia severity, hypoglycemia exposure, and glucose variability preceded sleep improvements.This trial is registered with ClinicalTrials.gov NCT03215914 https://clinicaltrials.gov/ct2/show/NCT03215914.
Keyphrases