Response of the human choroid to short-term changes in eyelid and periocular temperature.
Safal KhanalPhilip R K TurnbullLucia KimJohn R PhillipsPublished in: Clinical & experimental optometry (2024)
Cooling the anterior eye by application of a cold stimulus directly onto the closed eyelid caused a small but significant increase in choroidal thickness relative to warming the anterior eye, demonstrating that the choroid can modulate its thickness rapidly and transiently in response to local temperature changes.