Aerosol generation during general anesthesia is comparable to coughing: An observational clinical study.
Lotta-Maria A H OksanenEnni SanmarkSvetlana SofievaNoora RantanenMari LahelmaVeli-Jukka AnttilaLasse LehtonenNina AtanasovaEero PesonenAhmed GeneidAntti-Pekka HyvärinenPublished in: Acta anaesthesiologica Scandinavica (2022)
The list of aerosol-generating procedures guides the use of protective equipments in hospitals. Intubation is listed as a high-risk aerosol-generating procedure, however, aerosol generation has not been measured thoroughly. We measured aerosol generation during general anesthesia. None of the general anesthesia procedures generated statistically more aerosols than coughing and thus should not be considered as higher risk compared to normal respiratory activities.