Login / Signup

Fibroblast Cell Responses to Vanadium and Niobium Titanium Alloys: A Biocompatibility Study.

Ayse Ak
Published in: ACS omega (2023)
The interactions of a biomaterial with tissues must be determined for the material to be fully compatible with the body for a long time. The tissue and environment where the material is implanted are highly affected by its content. Titanium-6Aluminum-4Vanadium is widely used in orthopedics and dentistry. Recently, Titanium-6Aluminum-7Niobium alloys have been studied because of Titanium-6Aluminum-4Vanadium toxicity, which may be caused by vanadium. The aim of this study was to determine whether Titanium-6Aluminum-4Vanadium and Titanium-6Aluminum-7Niobium affect fibroblast cell proliferation, mineralization, and collagen production and whether they change the expression of type 1 collagen and fibronectin genes. It was determined that the niobium-containing alloy increased cell proliferation and calcium mineralization compared with the vanadium-containing alloy ( p < 0.05). However, the alloys did not cause changes in the expression of collagen type 1 or fibronectin in cells. The collagen content of the cells on the niobium-containing alloy was lower than that on both the vanadium-containing alloy and tissue culture plate surface ( p < 0.05). The niobium-containing alloy was found to be superior to the vanadium-containing alloy in terms of cell proliferation and calcium mineralization. Furthermore, neither vanadium-containing alloy nor niobium-containing alloy implant materials altered gene expression. Although both alloys are considered compatible with bone tissue, it should be considered whether they are also biocompatible with fibroblast cells.
Keyphrases