Analysis of Chest-Compression Depth and Full Recoil in Two Infant Chest-Compression Techniques Performed by a Single Rescuer: Systematic Review and Meta-Analysis.
Chun-Yu ChangPo-Chen LinYung-Jiun ChienChien-Sheng ChenMeng-Yu WuPublished in: International journal of environmental research and public health (2020)
Pediatric cardiac arrest is associated with high mortality and permanent neurological injury. We aimed to compare the effects of the two-thumb (TT) and two-finger (TF) techniques in infant cardiopulmonary resuscitation (CPR) performed by a single rescuer. We searched PubMed, EMBASE, and CENTRAL for randomized control trials published before December 2019. Studies comparing the TT and TF techniques in infant CPR were included for meta-analysis. Relevant information was extracted for methodological assessment. Twelve studies were included. The TT technique was associated with deeper chest-compression depth (mean difference: 4.71 mm; 95% confidence interval: 3.61 to 5.81; p < 0.001) compared with the TF technique. The TF technique was better in terms of the proportion of complete chest recoil (mean difference: -11.73%; 95% confidence interval: -20.29 to -3.17; p = 0.007). CPR was performed on a manikin model, and the application of the results to real human beings may be limited. The TT technique was superior to the TF technique in terms of chest-compression depth, but with inferior chest full recoil. Future investigations should focus on modifying the conventional TT technique to generate greater compression depth and achieve complete chest recoil.