The Effect of Ventilation with Individualized Positive End-Expiratory Pressure on Postoperative Atelectasis in Patients Undergoing Robot-Assisted Radical Prostatectomy: A Randomized Controlled Trial.
Hyun-Kyu YoonBo Rim KimSusie YoonYoung Hyun JeongJa Hyeon KuWon Ho KimPublished in: Journal of clinical medicine (2021)
For patients undergoing robot-assisted radical prostatectomy, the pneumoperitoneum with a steep Trendelenburg position could worsen intraoperative respiratory mechanics and result in postoperative atelectasis. We investigated the effects of individualized positive end-expiratory pressure (PEEP) on postoperative atelectasis, evaluated using lung ultrasonography. Sixty patients undergoing robot-assisted radical prostatectomy were randomly allocated into two groups. Individualized groups (n = 30) received individualized PEEP determined by a decremental PEEP trial using 20 to 7 cm H2O, aiming at maximizing respiratory compliance, whereas standardized groups (n = 30) received a standardized PEEP of 7 cm H2O during the pneumoperitoneum. Ultrasound examination was performed on 12 sections of thorax, and the lung ultrasound score was measured as 0-3 by considering the number of B lines and the degree of subpleural consolidation. The primary outcome was the difference between the lung ultrasound scores measured before anesthesia induction and just after extubation in the operating room. An increase in the difference means the development of atelectasis. The optimal PEEP in the individualized group was determined as the median (interquartile range) 14 (12-18) cm H2O. Compared with the standardized group, the difference in the lung ultrasound scores was significantly smaller in the individualized group (-0.5 ± 2.7 vs. 6.0 ± 2.9, mean difference -6.53, 95% confidence interval (-8.00 to -5.07), p < 0.001), which means that individualized PEEP was effective to reduce atelectasis. The lung ultrasound score measured after surgery was significantly lower in the individualized group than the standardized group (8.1 ± 5.7 vs. 12.2 ± 4.2, mean difference -4.13, 95% confidence interval (-6.74 to -1.53), p = 0.002). However, the arterial partial pressure of the oxygen/fraction of inspired oxygen levels during the surgery showed no significant time-group interaction between the two groups in repeated-measures analysis of variance (p = 0.145). The incidence of a composite of postoperative respiratory complications was comparable between the two groups. Individualized PEEP determined by maximal respiratory compliance during the pneumoperitoneum and steep Trendelenburg position significantly reduced postoperative atelectasis, as evaluated using lung ultrasonography. However, the clinical significance of this finding should be evaluated by a larger clinical trial.
Keyphrases
- patients undergoing
- robot assisted
- radical prostatectomy
- prostate cancer
- minimally invasive
- magnetic resonance imaging
- clinical trial
- mechanical ventilation
- randomized controlled trial
- intensive care unit
- contrast enhanced ultrasound
- computed tomography
- respiratory tract
- open label
- phase iii
- extracorporeal membrane oxygenation
- atrial fibrillation
- atomic force microscopy