Clinical and echocardiographic risk factors for device-related thrombus after left atrial appendage closure: an analysis from the multicenter EUROC-DRT registry.
Vivian VijKerstin PiaydaDominik NellesSteffen GloeklerRoberto GaleaMonika FürholzBernhard MeierMarco ValgimigliGilles O'HaraDabit ArzamendiVictor AgudeloLluis AsmaratsXavier FreixaEduardo Flores-UmanzorOle De BackerLars SondergaardLuis Nombela-FrancoAngela McInerneyKasper KorsholmJens Erik Nielsen-KudskShazia AfzalTobias ZeusFelix OperhalskiBoris SchmidtGilles MontalescotPaul GuedeneyXavier IriartNoelie MitonJacqueline SawThomas GilhoferLaurent FauchierEgzon VeliqiFelix MeinckeNils PetriPeter NordbeckDmitrii OgnerubovEvgeny MerkulovIgnacio Cruz-GonzálezRocio Gonzalez-FerreiroDeepak L BhattAlessandra LaricchiaAntonio MangieriHeyder OmranJan Wilko SchrickelJosep Rodes-CabauHorst SievertGeorg NickenigAlexander SedaghatPublished in: Clinical research in cardiology : official journal of the German Cardiac Society (2022)
DRT after LAAC is associated with adverse outcome and appears to be of multifactorial origin, depending on patient characteristics, anticoagulation regimen and device position.