Login / Signup

Assessment of a 60-Biomarker Health Surveillance Panel (HSP) on Whole Blood from Remote Sampling Devices by Targeted LC/MRM-MS and Discovery DIA-MS Analysis.

Stephen A WhelanNathan HendricksZachary L DwightQin FuAnnie MoradianJennifer E Van EykSusan M Mockus
Published in: Analytical chemistry (2023)
Telehealth, accessing healthcare and wellness remotely, should be a cost-effective and efficient way for individuals to receive care. The convenience of having a reliable remote collection device for blood tests will facilitate access to precision medicine and healthcare. Herein, we tested a 60-biomarker health surveillance panel (HSP), containing 35 FDA/LDT assays and covering at least 14 pathological states, on 8 healthy individuals' ability to collect their own capillary blood from a lancet finger prick and directly compared it to the traditional phlebotomist venous blood and plasma collection methods. All samples were spiked with 114 stable-isotope-labeled (SIL) HSP peptides and quantitatively analyzed by liquid chromatography-multiple reaction monitoring-mass spectrometry (LC/MRM-MS) scheduled method targeting 466 transitions from 114 HSP peptides and by a discovery data-independent acquisition mass spectrometry (DIA-MS) method. The average peak area ratio (PAR) of the HSP quantifier peptide transitions from all 8 volunteers' capillary blood ( n = 48), venous blood ( n = 48), and matched plasma ( n = 24) was <20% coefficients of variation (CV). Heat map analysis of all 8 volunteers demonstrated that each individual had a unique biosignature. Biological replicates from capillary blood and venous blood clustered within each volunteer in k -means clustering analysis. Pearson statistical analysis of the three biofluids indicated that there was >90% similarity. Discovery DIA-MS analysis of the same samples using a plasma spectral library and a pan-human spectral library identified 1121 and 4661 total proteins, respectively. In addition, at least 122 FDA-approved biomarkers were identified. DIA-MS analysis reproducibly quantitated (<30% CV) ∼600-700 proteins in capillary blood, ∼800 proteins in venous blood, and ∼300-400 proteins in plasma, demonstrating that an expansive biomarker panel is possible with current mass spectrometry technology. Both targeted LC/MRM-MS and discovery DIA-MS analysis of whole blood collected on remote sampling devices are viable options for personal proteome biosignature stratification in precision medicine and precision health.
Keyphrases