Assessment of temperatures in the vaccine cold chain in two provinces in Lao People's Democratic Republic: a cross-sectional pilot study.
Tomomi KitamuraViraneth BouakhasithKongxay PhounphenghackChansay PathammavongAnonh XeuatvongsaMasataro NorizukiHironori OkabayashiYoshio MoriMunehito MachidaMasahiko HachiyaPublished in: BMC research notes (2018)
The temperature remained within the appropriate range in the central and provincial storages. However, the vaccines were frequently exposed to > 8 °C in Saravan and < 0 °C in Xayabouly in the district storage. Vaccines were exposed to > 8 °C during the transportation in Saravan and to both > 8 and < 0 °C in Xayabouly. Thus, challenges in managing the cold chain in the district storage and during transportation remain, despite improvements at the provincial storage. A detailed up-to-date nationwide analysis of the current situation of the cold chain is warranted to identify the most appropriate intervention to tackle the remaining challenges.