Login / Signup

Failure Rate, Marginal Bone Loss, and Pink Esthetic with Socket-Shield Technique for Immediate Dental Implant Placement in the Esthetic Zone. A Systematic Review and Meta-Analysis.

Pilar Velasco BohórquezRoberta RuccoÁlvaro Zubizarreta-MachoJosé María Montiel-CompanySusana de la Vega BuróEsther Cáceres MadroñoLara San Hipólito MarínSofía Hernández Montero
Published in: Biology (2021)
Aim: To compare the failure rate, marginal bone loss, and pink esthetic for the socket-shield technique and the conventional technique for immediate dental implant placement in the esthetic zone. Material and methods: A systematic literature review and meta-analysis, based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated the failure rate, marginal bone loss, and pink esthetic with the socket-shield technique for immediate dental implant placement in the esthetic zone was performed. A total of 4 databases were consulted in the literature search: PubMed-MEDLINE, Scopus, Embase, and Web of Science. After eliminating duplicated articles and applying the inclusion criteria, 16 articles were selected for the qualitative and quantitative analysis. Results: Four randomized controlled trials, five prospective clinical studies, four retrospective studies, and three case series were included in the meta-analysis. The dental implant failure rate for the socket-shield technique for immediate dental implant placement was 1.37% (95% CI, 0.21-2.54%); however, no statistically significant differences between the conventional and socket-shield technique were found. The estimated mean difference in the marginal bone loss for the socket-shield technique was -0.5 mm (95% CI, -0.82 to -0.18) and statistically significant (p < 0.01), with a high heterogeneity (I2 = 99%). The mean pink esthetic score was 12.27 (Q test = 4.47; p-value = 0.61; I2 = 0%). The difference in pink esthetic between the conventional (n = 55) and socket-shield techniques (n = 55) for immediate dental implant placement was 1.15 (95% CI, 0.73-1.58; Q test = 8.88; p value = 0.11; I2 = 44%). The follow-up time was found to be significant (beta coefficient = 0.023; R2 = 85.6%; QM = 3.82; p = 0.049) for the PES for the socket-shield technique. Conclusions: Within the limitations of this systematic review with meta-analysis, the dental implant failure rate did not differ between the socket-shield technique and conventional technique for immediate implant placement in the esthetic zone. However, a lower marginal bone loss and higher pink esthetic scores were found for the socket-shield technique compared to the conventional technique.
Keyphrases