Changes in Peak Inspiratory Flow After Acute Bronchodilation: An Observational Study of Patients with Stable Chronic Obstructive Pulmonary Disease.
Roy A PleasantsAsif ShaikhAshley G HendersonValentina BayerM Bradley DrummondPublished in: Journal of aerosol medicine and pulmonary drug delivery (2024)
Introduction: Identifying factors influencing peak inspiratory flow (PIF) is essential for aerosol drug delivery in stable patients with chronic obstructive pulmonary disease. While a minimum PIF for dry powder inhalers (DPIs) is established, acute bronchodilator (BD) effects on PIF remain unknown. Materials and Methods: An inspiratory flow meter (In-Check™ DIAL) was used to measure PIF in stable patients during a 24-week observational cross-sectional study. Additionally, bronchodilator responsiveness (BDR) was determined using the In-Check DIAL device and spirometry. Patients received four puffs of albuterol, and pre- and post-BD PIF, forced expiratory volume in one second (FEV 1 ), and forced vital capacity were measured. Sixty-three patients completed acute BDR data collection from July 31, 2019, to November 9, 2021. Primary endpoints were pre- and post-BD spirometry and PIF. Statistical analyses included PIF correlations with FEV 1 . BD change was assessed according to inhaler resistance and sex (subgroup analysis). Results: Median patient age was 64.8 years, 85.7% were non-Hispanic White, and 57.1% were female. The median increase in absolute PIF (In-Check DIAL) was 5.0 L/min, and the % PIF change was 8.9%. With albuterol, 57.1% experienced a PIF BD change >5.0%, whereas 49.2% experienced a change >10.0%. Similarly, 55.6% experienced an FEV 1 BD change >5.0% and 28.6% had a >10.0% FEV 1 BD change with albuterol. PIF was weakly correlated with FEV 1 BD change (absolute; % PIF; r = 0.28 [ p = 0.02]; r = 0.21 [ p = 0.11]). Pre- and post-BD median PIF were 75.5 and 83.5 L/min for low-to-medium-resistance DPI and 45.0 and 52.0 L/min for high-resistance, respectively. The median increases in pre- and post-BD PIF were 9.0 L/min in males and 4.5 L/min in females. In contrast to when using the In-Check DIAL device, we observed no consistent bronchodilatory effects on PIF measured by spirometry. Conclusions: Using the In-Check DIAL device, ∼50% of patients experienced >10% PIF increase after acute BD, potentially enhancing medication lung deposition. Further research is required to understand PIF's impact on medication delivery. ClinicalTrials.gov Identifier: NCT04168775.
Keyphrases
- end stage renal disease
- ejection fraction
- chronic obstructive pulmonary disease
- drug delivery
- newly diagnosed
- chronic kidney disease
- prognostic factors
- healthcare
- randomized controlled trial
- computed tomography
- magnetic resonance imaging
- emergency department
- machine learning
- magnetic resonance
- intensive care unit
- lung function
- cystic fibrosis
- electronic health record
- cross sectional
- acute respiratory distress syndrome